SPRS698D – NOVEMBER 2010 – REVISED DECEMBER 2012
6
Revision History
This data sheet revision history highlights the technical changes made to the SPRS698C device-specific
data sheet to make it an SPRS698D revision.
Scope:
The TMS320F2806xU devices are now "TMS" devices (fully qualified production devices). See
Information/data on TMS320F2806xU devices are now Production Data.
PRODUCTION DATA information is current as of publication date. Products conform to
specifications per the terms of the Texas Instruments standard warranty. Production processing
does not necessarily include testing of all parameters.
Q-temperature devices are "TMX" devices (experimental devices). See
Section 3.3 for more
information on device status.
The "Q" temperature option (–40°C to 125°C) is not available on the TMS320F2806xU
devices.
See table below.
LOCATION
ADDITIONS, DELETIONS, AND MODIFICATIONS
Hardware Features:
Changed "ePWM outputs" for the 100-Pin PZ and PZP packages for all devices from 19 to 16
Changed "ePWM outputs" for the 80-Pin PN and PFP packages for all devices from 15 to 14
Updated "Product status" row
Added "Product status for Q-temperature devices" row
Added "The "Q" temperature option is not available on the TMS320F2806xU devices" footnote
Added footnote about "TMX" product status
Peripheral Frame 0 Registers:
PIE Vector Table: Changed "EALLOW PROTECTED" value from "No" to "Yes"
Device Emulation Registers:
Removed "For TMS320F28069U devices, the PARTID and CLASSID numbers are also used for TMX
devices. In the case of TMX320F28069UPFPA and TMX320F28069UPZPA devices, the temperature rating is
'A' instead of 'T'" footnote
PLL Settings:
Added data for PLLCR[DIV] VALUE = 10001
Added data for PLLCR[DIV] VALUE = 10010
Possible PLL Configuration Modes:
Removed "PLLSTS[DIVSEL] should not be set to /1 mode while the PLL is enabled" footnote
Device Nomenclature:
Added "The "Q" temperature option is not available on the 2806xU devices" footnote
Recommended Operating Conditions:
Changed "VDDIO and VDDA should be maintained within ~0.3 V of each other" footnote to "VDDIO and VDDA
should be maintained within approximately 0.3 V of each other"
Added "The "Q" temperature option is not available on the 2806xU devices" footnote
Device Clocking Requirements/Characteristics:
External oscillator/clock source (XCLKIN pin) — PLL Disabled:
–
tc(CI), Cycle time (C8): Changed MIN value from 33.33 ns to 11.11 ns
–
Frequency: Changed MAX value from 30 MHz to 90 MHz
XCLKIN Timing Requirements - PLL Disabled:
C9, tf(CI): Changed frequency range from "20 MHz to 30 MHz" to "20 MHz to 90 MHz"
C10, tr(CI): Changed frequency range from "20 MHz to 30 MHz" to "20 MHz to 90 MHz"
Power Sequencing:
Removed "Furthermore, VDDIO and VDDA should always be within 0.3 V of each other" sentence from "There
is no power sequencing requirement needed ..." paragraph
Copyright 2010–2012, Texas Instruments Incorporated
Revision History
157