参数资料
型号: MMA7660FCT
厂商: Freescale Semiconductor
文件页数: 13/35页
文件大小: 0K
描述: ACCELEROMETER 3X3 DGTL 10-DFN
特色产品: MMA7660 Digital Output Accelerometer
标准包装: 490
轴: X,Y,Z
加速范围: ±1.5g
灵敏度: 21.33 计数/g
电源电压: 2.4 V ~ 3.6 V
输出类型: 数字
接口: I²C
安装类型: 表面贴装
封装/外壳: 10-VFDFN
供应商设备封装: 10-DFN(3x3)
产品目录页面: 2805 (CN2011-ZH PDF)
Tap Detection
The MMA7660FC also includes a Tap Detection feature that can be used for a number of different customer applications such
as button replacement. For example, a single tap can stop a song from playing and a double tap can play a song. This function
detects a fast transition that exceeds a user-defined threshold (PDET (0x09) register) for a set duration (PD (0x0A) register).
Tap Detection Setup
In order to enable Tap detection in the device the user must enable the Tap Interrupt in the INTSU (0x06) register and AMSR
[2:0] = 000 in the SR (0x08) register. In this mode, TILT (0x03) register, XOUT (0x00), YOUT (0x01), and ZOUT (0x02) registers
will update at the 120 samples/second.
The user can configure Tap Detection to be detected on X and/or Y and/or Z axes. The customer can configure this by
changing the XDA, YDA, and/or ZDA bit in the PDET (0x09) register. Detection for enabled axes is decided on an OR basis: If
the PDINT bit is set in the INTSU (0x06) register, the device reports the first axis for which it detects a tap by the Tap bit in the
TILT (0x03) register. When the Tap bit in the TILT (0x03) register is set, tap detection ceases, but the device will continue to
process orientation detection data. Tap detection will resume when the TILT (0x03) register is read.
NOTE: Delta G is available with any AMSR setting, when XDA = YDA = ZDA = 1 (PDET = 1). When the sampling rate
is less than 120 samples/second, the device can not detect tapping, but can detect small tilt angles (30 o angle
change) which can not be detected by orientation detection.
Shake Detection
The shake feature can be used as a button replacement to perform functions such as scrolling through images or web pages
on a Mobile Phone/PMP/PDA. The customer can enable the shake interrupt on any of the 3 axes, by enabling the SHINTX,
SHINTY, and/or SHINTZ in the INTSU (0x06) register.
MMA7660FC detects shake by examining the current 6-bit measurement for each axis in XOUT, YOUT, and ZOUT. The axes
that are tested for shake detection are the ones enabled by SHINTX, SHINTY, and/or SHINTZ. If a selected axis measures
greater that 1.3 or less than -1.3 g, then a shake is detected for that axis and an interrupt occurs. All three axes are checked
independently, but a common Shake bit in the TILT register is set when shake is detected in any one of the selected axes.
Therefore when all three (SHINTX, SHINTY, and/or SHINTZ) are selected the sensor will not know what axis the shake occurred.
When the TILT register is read the Shake bit is cleared during the acknowledge bit of the read access to that register and shake
detection monitoring starts again.
Auto-Wake/Sleep
The MMA7660FC has the Auto-Wake/Sleep feature that can be enabled for power saving. In the Auto-Wake function, the
device is put into a user specified low samples per second (1 sample/second, 8 samples/second, 16 samples/second, or
32 samples/second) in order to minimize power consumption. When the Auto-Wake is enabled and activity is detected such as
a change in orientation, pulse event, Delta G acceleration or a shake event, then the device wakes up. Auto-Wake will
automatically enable Auto-Sleep when the device is in wake mode and can therefore be configured to cause an interrupt on
wake-up, by configuring the part to either wake-up with a change in orientation, shake, or if using the part at 120 samples/second
tap detection. When the device is in Auto-Wake mode, the MODE (0x07) register, bit AWE is high. When the device has detected
a change in orientation, a tap shake, or Delta G (change in acceleration), the device will enter Auto-Sleep mode. In the Auto-
Sleep function, the device is put into any of the following user specified samples per seconds (1 sample/second, 2 samples/
second, 4 samples/second, 8 samples/second, 16 samples/second, 32 samples/second, 64 samples/second, and 120 samples/
second). In the Auto-Sleep mode, if no change in the orientation, shake or tap has occurred and the sleep counter has elapsed,
the device will go into the Auto-Wake mode. When the device is in the Auto-Sleep mode, the MODE (0x07) register, bit ASE is
high. The device can be programmed to continually cycle between Auto-Wake/Sleep.
NOTE: The device can either be powered on in Wake/Sleep state depending on ASE/AWE settings. If the AWE bit is
set, the device is powered on in, in sleep state. If the ASW bit is set, the device is powered on in, in wake state.
Table 8. Auto-Wake/Sleep Truth Table
Trigger Wake-up
Reset Sleep Counter
Trigger Sleep Mode
Orientation Detection Change
Shake
Delta G
(set with PD (0x0A) and PDET (0x09))
Pulse Detect (120 samples/second)
Sleep Counter Elapsed
Yes
Yes
Yes
(XDA = YDA = ZDA = 0)
Yes
No
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
MMA7660FC
Sensors
13
Freescale Semiconductor, Inc.
相关PDF资料
PDF描述
DPL04 PIANO STYLE DIP SWITCH
551-0307F LED 3MM HIGH EFF YELLOW
90GB10LT SWITCH 10POS DIP AUTODIP
550-0207F LED 5MM RT ANGLE GREEN PC MNT
A6SN-4101-P SWITCH DIP 4POS FLUSH ACT SMD
相关代理商/技术参数
参数描述
MMA7660FCT 制造商:Freescale Semiconductor 功能描述:IC 3 AXIS ACCELEROMETER ?1.5G DFN-10
MMA8104EG 功能描述:加速计 - 板上安装 SOURCE ONLY RoHS:否 制造商:Murata 传感轴:Double 加速:12 g 灵敏度: 封装 / 箱体: 输出类型:Analog 数字输出 - 位数:11 bit 电源电压-最大:5.25 V 电源电压-最小:4.75 V 电源电流:4 mA 最大工作温度:+ 125 C 最小工作温度:- 40 C
MMA8104EGR2 功能描述:加速计 - 板上安装 Z-AXIS 40G W/CAP BOND RoHS:否 制造商:Murata 传感轴:Double 加速:12 g 灵敏度: 封装 / 箱体: 输出类型:Analog 数字输出 - 位数:11 bit 电源电压-最大:5.25 V 电源电压-最小:4.75 V 电源电流:4 mA 最大工作温度:+ 125 C 最小工作温度:- 40 C
MMA8104KEG 功能描述:加速计 - 板上安装 SOURCE ONLY RoHS:否 制造商:Murata 传感轴:Double 加速:12 g 灵敏度: 封装 / 箱体: 输出类型:Analog 数字输出 - 位数:11 bit 电源电压-最大:5.25 V 电源电压-最小:4.75 V 电源电流:4 mA 最大工作温度:+ 125 C 最小工作温度:- 40 C
MMA8104KEGR2 功能描述:加速计 - 板上安装 Z-AXIS 40G W/CAP BOND RoHS:否 制造商:Murata 传感轴:Double 加速:12 g 灵敏度: 封装 / 箱体: 输出类型:Analog 数字输出 - 位数:11 bit 电源电压-最大:5.25 V 电源电压-最小:4.75 V 电源电流:4 mA 最大工作温度:+ 125 C 最小工作温度:- 40 C