Chapter 1 – AT Commands, S-Registers, and Result Codes
\X
Description:
Syntax:
Values:
Default:
Result Codes:
-C
Description:
Syntax:
Values:
Default:
Result Codes:
%A
Description:
Syntax:
Values:
Default:
Result Codes:
%B
Description:
Syntax:
Values:
Result Codes:
XON/XOFF Pass-Through
Use this command to restrict the XON/XOFF flow control to the local DCE for
processing or to have the local DCE send the flow control characters to the remote
DCE.
AT\X<value>
0 Modem processes XON/XOFF flow control characters locally.
1 Modem passes XON/XOFF flow control characters.
0
OK if <value> = 0, 1.
ERROR if <value> ≠ 0, 1.
Data Calling Tone
Enables/disables the V.25 data calling tone to deny/allow data/fax/voice discrimination.
AT-C<value>
0 Disable V.25 data calling tone to deny remote data/fax/voice discrimination.
1 Enable V.25 data calling tone to allow remote data/fax/voice discrimination.
1
OK if <value> = 0, 1.
ERROR if <value> ≠ 0, 1.
Adaptive Answer Result Code Enable
The %A command controls whether the DATA or FAX result codes will be sent by the
modem. The modem must be in fax mode for this command to work. Also, the
modem must be set to +FAA=1 , which enables the modem to distinguish between a
fax and a data call. When these commands are enabled, the modem sends DATA to
the computer when it detects data tones and FAX when it detects fax tones. These
strings are used by some servers to select the appropriate communication program..
AT%A<value>
0 Disables adaptive answer result codes.
1 Enables adaptive answer result codes.
0
OK if <value> = 0, 1.
ERROR if <value> ≠ 0, 1
View Numbers in Blacklist
Blacklisting is a method of handling failed or troubled calls encountered during
automatic dialing. This command is only used to display the contents of the blacklist
when blacklisting is active. It does not affect the functionality associated with
blacklisting.
When the blacklisting option is active, use this command to display the telephone
numbers and status of any failed or troubled calls. The blacklisting option is
associated with the country selection. Some countries have national requirements
which prohibit repeat calls to the same number through automatic dialing.
AT%B
N/A
<list of phone numbers and their status> if country supports blacklisting.
OK if no failed calls occur.
ERROR if country selection does not support blacklisting.
Multi-Tech Systems, Inc. AT Commands for the MultiModem & SocketModem MT9234 Series (S000434H)
20
相关PDF资料
PDF描述
G5NB-1A DC12 RELAY GEN PURPOSE SPST 3A 12V
284415-8 TERM BLOCK RCPT 8POS R/A 3.81MM
284414-8 TERM BLOCK RCPT 8POS R/A 3.50MM
1-282837-2 TERM BLOCK RCPT 12POS VERT .200
1-1546216-2 TERM BLOCK RCPT 12POS VERT 5MM
相关代理商/技术参数
参数描述
MT9234MU-CDC-XR 功能描述:MODEM V.92 DATA/FAX USB WORLD RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiMobile™ USB 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT9234MU-CDC-XR-CP 制造商:Multi-Tech Systems 功能描述:V.92 DATA/FAX WORLD MODEM (USB) (25 MODEMS) - Bulk
MT9234SMI 制造商:MULTI TECH SYSTEM 功能描述:
MT9234SMI-92 功能描述:拨号模块 V.92 Serial Data V.34 FAX - 5V RoHS:否 制造商:Multi-Tech Systems 产品:Data / Fax Modems 最大数据速率:56 kbps 存储类型:Flash 接口类型:Serial 工作电源电压:3.3 V 工作电源电流:95 mA 功耗:310 mW 最大工作温度:+ 70 C 尺寸:64.5 mm x 26.5 mm x 17 mm
MT9234SMI-92.R1 功能描述:拨号模块 V.92 Serial Data V.34 Fax 5V RoHS:否 制造商:Multi-Tech Systems 产品:Data / Fax Modems 最大数据速率:56 kbps 存储类型:Flash 接口类型:Serial 工作电源电压:3.3 V 工作电源电流:95 mA 功耗:310 mW 最大工作温度:+ 70 C 尺寸:64.5 mm x 26.5 mm x 17 mm