参数资料
型号: MT9234MU-CDC-CP
厂商: Multi-Tech Systems
文件页数: 16/66页
文件大小: 0K
描述: MODEM V.92 DATA/FAX USB WORLD 25
标准包装: 1
系列: MultiMobile™ USB
数据格式: V.34,V.92
安装类型: 台式
封装/外壳: 3.1" L x 1.3" W x 1.0" H(80mm x 30mm x 25mm)
包装: 散装
Chapter 1 – AT Commands, S-Registers, and Result Codes
&Q
Description:
Syntax:
Values:
Default:
Result Codes:
&S
Description:
Syntax:
Values:
Default:
Result Codes:
&T
Description:
Syntax:
Values:
Default:
Result Codes:
&V
Description:
Syntax:
Asynchronous Communications Mode
This command is supported to ensure backward compatibility with communication
software that issues the &Q command. The preferred method for changing the
asynchronous communication mode is to use the \N command.
AT&Q<value>
0 Asynchronous with data buffering. Same as \N0 .
5 Error control with data buffering. Same as \N3 .
6 Asynchronous with data buffering. Same as \N0 .
8 MNP error control mode. If MNP error control is not established, the modem
falls back according to the setting in S36 .
9 V.42 or MNP error control mode. If neither error control is established, the
modem falls back according to the setting in S36 .
5
OK if <value> = 0, 5, 6, 8, or 9.
ERROR if <value> ≠ 0, 5, 6, 8, or 9.
Data Set Ready (DSR)
Use this command to control DSR action.
AT&S<value>
0 DSR is always ON.
1 DSR goes ON only during a connection.
0
OK if <value> = 0,1.
ERROR if <value> ≠ 0, 1.
Self-Test Commands
Use this command to perform diagnostic tests on the modem. Each test is designed
to isolate a problem location when experiencing periodic data loss or random errors.
AT&T<value>
0 Terminates the test in progress.
1 The &T1 command runs the Local Analog Loopback Test. This test verifies
modem's transmitter and receiver circuits are functioning properly. To work
properly, the modem must be off-line.
3 The AT3 runs the Local Digital Loopback Test. This test allows you to verify
that the remote computer or terminal, the remote modem, serial ports, the
telephone line, and the local modem are functioning properly. To work
properly, the modem must be online.
4 The &T4 command must be sent to the remote modem to run the Remote
Digital Loopback Test.
6 The &T6 command runs the Remote Digital Loopback Test. This test allows
you to verify that the local computer or terminal, the two modems, and the
transmission line between them are functioning properly. To work properly,
the modem must be online.
None
OK if <value> = 0.
CONNECT if <value> = 0 or 3.
ERROR if <value> ≠ 0, 1, or 3.
View Active Configuration
Use this command to view the active configuration.
AT&V
Multi-Tech Systems, Inc. AT Commands for the MultiModem & SocketModem MT9234 Series (S000434H)
16
相关PDF资料
PDF描述
G5NB-1A DC12 RELAY GEN PURPOSE SPST 3A 12V
284415-8 TERM BLOCK RCPT 8POS R/A 3.81MM
284414-8 TERM BLOCK RCPT 8POS R/A 3.50MM
1-282837-2 TERM BLOCK RCPT 12POS VERT .200
1-1546216-2 TERM BLOCK RCPT 12POS VERT 5MM
相关代理商/技术参数
参数描述
MT9234MU-CDC-XR 功能描述:MODEM V.92 DATA/FAX USB WORLD RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiMobile™ USB 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT9234MU-CDC-XR-CP 制造商:Multi-Tech Systems 功能描述:V.92 DATA/FAX WORLD MODEM (USB) (25 MODEMS) - Bulk
MT9234SMI 制造商:MULTI TECH SYSTEM 功能描述:
MT9234SMI-92 功能描述:拨号模块 V.92 Serial Data V.34 FAX - 5V RoHS:否 制造商:Multi-Tech Systems 产品:Data / Fax Modems 最大数据速率:56 kbps 存储类型:Flash 接口类型:Serial 工作电源电压:3.3 V 工作电源电流:95 mA 功耗:310 mW 最大工作温度:+ 70 C 尺寸:64.5 mm x 26.5 mm x 17 mm
MT9234SMI-92.R1 功能描述:拨号模块 V.92 Serial Data V.34 Fax 5V RoHS:否 制造商:Multi-Tech Systems 产品:Data / Fax Modems 最大数据速率:56 kbps 存储类型:Flash 接口类型:Serial 工作电源电压:3.3 V 工作电源电流:95 mA 功耗:310 mW 最大工作温度:+ 70 C 尺寸:64.5 mm x 26.5 mm x 17 mm