71M6513/71M6513H Demo Board User’s Manual
Step 1: Basic Calibration : After making sure VFEED_A , VFEED_B , and VFEED_C are zero, perform either the
three measurement procedure (2.2.1) or the five measurement calibration procedure (2.2.2) described in the CT
section. Perform the procedure at a current large enough that energy readings are immune from voltage
coupling effects.
The one exception to the CT procedure is the equation for PHADJ—after the phase error, φ s, has been
calculated, use the PHADJ equation shown below. Note that the default value of PHADJ is not zero, but rather –
3973.
PHADJ = PHADJ PREVIOUS ? φ S 1786
50
f 0
If voltage coupling at low currents is introducing unacceptable errors, perform step 2 below to select non-zero
values for VFEED_A , VFEED_B , and VFEED_C .
Step 2: Voltage Cancellation: Select a small current, I RMS , where voltage coupling introduces at least 1.5%
energy error. At this current, measure the errors E 0 and E 180 to determine the coefficient VFEED .
E 0 ? E 180 25 I RMS V MAX
VFEED =
2 I MAX V RMS
2
? VFEED PREVIOUS
2.2.4 CALIBRATION SPREADSHEETS
Calibration spreadsheets are available from TERIDIAN Semiconductor. They are also included in the CD-ROM
shipped with any Demo Kit. Figure 2-3 shows the spreadsheet for three measurements. Figure 2-4 shows the
spreadsheet for five measurements with three phases.
For CT and shunt calibration, data should be entered into the calibration spreadsheets as follows:
1.
2.
3.
4.
5.
6.
7.
Calibration is performed one phase at a time.
Results from measurements are generally entered in the yellow fields. Intermediate results and
calibration factors will show in the green fields.
The line frequency used (50 or 60Hz0 is entered in the yellow field labeled AC frequency.
After the voltage measurement, measured (observed) and expected (actually applied) voltages are
entered in the yellow fields labeled “Expected Voltage” and “Measured Voltage”. The error for the
voltage measurement will then show in the green field above the two voltage entries.
The relative error from the energy measurements at 0° and 60° are entered in the yellow fields labeled
“Energy reading at 0°” and “Energy reading at 60°”. The corresponding error, expressed as a fraction
will then show in the two green fields to the right of the energy reading fields.
The spreadsheet will calculate the calibration factors CAL_IA, CAL_VA, and PHADJ_A from the
information entered so far and display them in the green fields in the column underneath the label
“new”.
If the calibration was performed on a meter with non-default calibration factors, these factors can be
entered in the yellow fields in the column underneath the label “old”.
For a meter with default calibration factors, the entries in the column underneath “old” should be at the
default value (16384).
Page: 49 of 112
? 2005-2006 TERIDIAN Semiconductor Corporation
Revision 5.6
相关PDF资料
PDF描述
71M6515H-DB BOARD DEMO 71M6515H ENERGY METER
71M6521FE-DB BOARD DEMO FOR 71M6521FE
71M6531F-DB BOARD DEMO 71M6531F
71M6533-DB BOARD DEMO 71M6533
71M6534H-DB BOARD DEMO 71M6534H
相关代理商/技术参数
参数描述
71M6513H-IEL 制造商:未知厂家 制造商全称:未知厂家 功能描述:71M6513
71M6513H-IEL/F 功能描述:计量片上系统 - SoC 3-Phase Energy Meter I/C RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6513H-IELR 功能描述:计量片上系统 - SoC 3-Phase Energy Meter I/C RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6513H-IELR/F 功能描述:计量片上系统 - SoC 3-Phase Energy Meter I/C RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6513H-IGT/F 功能描述:计量片上系统 - SoC 3-Phase Energy Meter I/C RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel