参数资料
型号: 0638017200
厂商: Molex Inc
文件页数: 16/24页
文件大小: 0K
描述: CRMP PRESS TM3000 120V TO 10AWG
其它有关文件: Overlap Style Insulation Crimps
标准包装: 1
系列: TM-3000
工具类型: 台式压机,气动 - 无喷枪
适用于相关产品: FineAdjust? 和 Mini-Mac? 施用器
配用: 638027600-ND - MINI MAC APPLICATOR 14-16 AWG
638027500-ND - MINI MAC APPLICATOR 18-22 AWG
638027200-ND - MINI MAC APPLICATOR 14-18 AWG
638027100-ND - MINI MAC APPLICATOR 14-18 AWG
638027000-ND - MINI MAC APPLICATOR 14-18 AWG
638026900-ND - MINI MAC APPLICATOR 14-18 AWG
0639024800-ND - FINE ADJUST APPLICATOR
0639024700-ND - FINE ADJUST APPLICATOR
0639024600-ND - FINE ADJUST APPLICATOR
0639023900-ND - FINE ADJUST APPLICATOR
更多...
相关产品: WM5083-ND - GUARD TM-3000&4000 UNIV PRESS
WM5082-ND - TERMINAL OILER FOR TM-3000PRESS
WM6296-ND - TOOL PRESS SHUT HEIGHT GAUGE
其它名称: 063801-7200
063801-7200-E
0638017200-E
63801-7200
63801-7200-E
63801-7200-ND
638017200
638017200-E
WM4793
Quality Crimp Handbook
Two operators may measure the same part differently,
or the same operator may measure the part differently
when using two types of gauges. Molex recommends a
gauge capability study to identify what part of the
variability is coming from measurement error. Micro-
terminals crimped to small wire sizes need a tight crimp
height range to maintain pull force. The variability from
measurement error can keep C pk values low.
The capability of the crimping tools needs to be re-
confirmed if the production data is significantly different
changes, or setup adjustments. Record the data point
on the chart before making a crimp height adjustment.
If data is recorded after each adjustment, the process is
likely to assume control and provide little data for
improving the process. The operator needs to make as
many notes as possible on the chart. The only truly
effective and economically sensible way to manage a
manufacturing process is to understand, monitor and
reduce sources of variability that are inherent to the
process itself. Every minute required for setup or
adjustments is unproductive.
from the capability study.
What does this sample chart tell us?
Production
Before the tool is ready for production, the level of
capability needs to be established. Many harness
manufacturers run only a few hundred or few thousand
wires at one time. In this case, it is not practical or
economical to run a twenty-five-piece capability with
every set-up.
Visual Inspection
X and R Chart
It needs to be standard operating procedure for the
operator to manually fan each bundle of crimped wires
and visually check bell mouth, conductor brush,
insulation position, cut-off tab length, and insulation
crimp.
Control Charting
Crimp height is typically control charted because it is a
quick nondestructive measurement and is critical for the
termination's electrical and mechanical reliability.
There are three primary purposes for control charting.
One, the number of setup samples is usually small, with
limited statistical value. Two, since special cause
effects on a process are irregular and unpredictable; it
is necessary to be able to catch changes in the process
as soon as they occur. This prevents thousands of
terminations from being scrapped after the run is over.
Three, and most important, this data is necessary to
assess and improve the crimp process.
Control limit for sample of 5 = Avg
(Avg of 5 readings) + .577 x Avg (Ranges)
It indicates that a process shift occurred between
measurement 12 and 13. This type of shift could occur
due to a change in wire, a change in terminal lots, a
jam in the machine that damaged the tooling, a change
in operators, or an adjustment to the insulation crimp.
Since the measurements are still within specification,
would you stop production to adjust crimp height?
A shift in the process due to a change in material may
warrant a crimp height adjustment. A shift after a jam
would not indicate an adjustment, but a close
evaluation of the tooling. A shift in the process
between operators would not indicate an adjustment,
but an evaluation of measurement capability. The
purpose of a control chart is to identify what caused the
shift in process to determine if an adjustment to the
process is needed.
Once the tooling process is setup and the wire size
does not change, keep one control chart for wire color
changes, wire length changes, terminal material
Order No: TM-638000029
Revision: D
Release Date: 09-04-03
Revision Date: 12-23-09
UNCONTROLLED COPY
Page 16 of 24
相关PDF资料
PDF描述
NDKR16H SW ROTARY DIP 8MM HEX RT ANG PC
MMA2260EGR2 SENSOR ACCEL X-AXIS 1.5G 16-SOIC
63811-8000 TOOL HAND CRIMP 22-28AWG
555-4003F LED 2MM QUAD 5V RED
555-4401F LED 2MM QUAD YELLOW
相关代理商/技术参数
参数描述
0638017205 功能描述:FACE PLATE 制造商:molex, llc 系列:* 零件状态:在售 标准包装:1
0638017206 功能描述:SWITCH TDC 制造商:molex, llc 系列:* 零件状态:过期 标准包装:1
0638017207 功能描述:SWITCH W CABLE TDC 制造商:molex, llc 系列:* 零件状态:在售 标准包装:1
0638017208 功能描述:ACCESS COVER 制造商:molex, llc 系列:* 零件状态:在售 标准包装:1
0638017211 制造商:Molex 功能描述:PROX SPLIT CYCLE 制造商:Molex 功能描述:PROX SPLIT CYCLE - Bulk 制造商:Molex 功能描述:PROX SPLIT CYCLE