参数资料
型号: LD2T06P0
厂商: Red Lion Controls
文件页数: 10/16页
文件大小: 0K
描述: TIMER 6 DIGIT 2.25" 120VAC RED
标准包装: 1
系列: LD
继电器类型: 集成式
功能: 可编程(多功能)
电路: SPDT(1 C 型)
输出类型: 机械式继电器
触点额定电压: 5A @ 120VAC
电源电压: 多电压
安装类型: 底座安装
端接类型: 螺丝端子
计时调节方法: DIP 开关,螺丝刀槽
计时启动方法: 输入电压
其它名称: RLC119
5.4 MODULE 4 - S ETPOINT O UTPUT P ARAMETERS ( ????? )
4-SPt
PAR
PARAMETER MENU
Pro
SP-ASN
Setpoint
SP-ACt
Setpoint
SP-ON
Setpoint On
SP-OFF
Setpoint Off
O-tOUt
Setpoint
StOP-t
Stop Timer
AUtO-r
Timer/Counter
OrSt-r
Setpoint
O P-UP
Setpoint
Assignment
Output Action
Output
Auto Reset
Output Reset
Output
Time-out
with Display
Reset
Power-up
State
Module 4 is the programming module for the Setpoint Output parameters.
Some parameters will not appear depending on the Setpoint Assignment and
Setpoint Output Action selected.
SETPOINT ASSIGNMENT
SETPOINT OUTPUT TIME-OUT
?????? ? ????????? to ? ?????????
? ????????
This parameter is only active if the Setpoint Action is set to Timed Output mode
?????? ?
? ?????
?????
?????
( ????? ). Enter the time duration the Setpoint Output will remain ON once it is
activated. This value is always entered in minutes, seconds, and hundredths of
seconds format. The maximum value is 99 minutes 59.99 seconds.
Select the display for Setpoint assignment.
STOP TIMER
?????? ?
?
?
??????
?
SETPOINT OUTPUT ACTION
?????
?????
????? ??????
This parameter selects the action of the Setpoint output as shown below.
??
????
?? ?????
Stops the Timer when the Setpoint output activates ( ???? ) or deactivates
( ????? ). Select ?? if the output should not affect the Timer Run/Stop status.
The Timer Stop condition is cleared when a Timer Reset occurs, or a Time
Start edge is applied on the Timer input.
SPT ACTION DESCRIPTION
OUTPUT ACTIVATES
OUTPUT DEACTIVATES
?????
Latched Output Mode
When Time or Count
= Setpoint On value
At Manual Reset
(if ?????? = ??? )
?
?????
??????
Timed Output Mode
On-Off Output Mode
When Time or Count After Setpoint
= Setpoint On value Output Time-Out
When Time or Count When Time or Count
?? Setpoint On value ?? Setpoint Off value
??????
?
TIMER/COUNTER AUTO RESET
??
????
?? ?????
Automatically resets the Setpoint Assigned display value when the Setpoint
SETPOINT ON
Output activates ( ???? ) or deactivates ( ????? ). Select ?? if the output should
????? ?
? ?????
?????
??????
??????
not cause a display reset.
This parameter determines when the Setpoint output will activate. The output
SETPOINT OUTPUT RESET WITH DISPLAY RESET
can activate at a programmed Setpoint Value or can be set to activate when the
Timer starts ( ?????? ) or stops ( ?????? ).
Selecting ????? displays a sub-menu where the Setpoint Value is entered. If
the Setpoint is assigned to the Timer, the value is entered in the same display
?????? ?
? ???
???
??
format as the selected Timer Range.
Select ??? to have the Setpoint Output deactivate (reset) when the Setpoint
?? ? ??? ?
? ??????
?????? to ??????
Assigned display resets. Reset can occur by the RST ? key or the User Input,
if programmed for that function. Select ?? if the Setpoint output should not
reset when the display resets.
?????? ?
?
?????
?
???
SETPOINT OFF
?????
??????
??????
The Setpoint Off parameter only appears if the Setpoint Action is set to
On-Off Output mode ( ?????? ). In this mode, the Setpoint OFF parameter
determines when the Setpoint Output will deactivate. The output can be
programmed to deactivate at a Setpoint Off Value or can be set to deactivate
when the Timer starts ( ?????? ) or stops ( ?????? ).
Selecting ????? displays a sub-menu where the Setpoint Off Value is
entered. If the Setpoint is assigned to the Timer, the value is entered in the same
display format as the selected Timer Range.
SETPOINT OUTPUT POWER-UP STATE
?? ???? ? ???
??
????
???? will restore the output to the same state it was at before the meter was
powered down. ?? will activate the output at power up. ??? will deactivate the
output at power up. This parameter is not active when the Setpoint Action is
selected for timed output mode.
?? ? ??? ?
? ??????
?????? to ??????
10
相关PDF资料
PDF描述
325312-08-0 TERM BARRIER 8CIRC SGL ROW .325
30R600UF PTC 6.00A 30V RESETTABLE KINK
325311-08-0 TERM BARRIER 8CIRC SGL ROW .325
1586317-3 CONN TERM SOCKET 22-26AWG TIN
325303-08-0 TERM BARRIER 8CIRC SGL ROW .325
相关代理商/技术参数
参数描述
LD3 制造商:Thomas & Betts 功能描述:3-Pole Disconnect Kit 制造商:Thomas & Betts 功能描述:PLUG & SOCKET CONNECTORKIT, 2 FEMALE-2 MALE, 3POS, Series:Sta-Kon Luminaire, Contact Termination:Crimp, No. of Contacts:3, No. of Rows:1, Connector Mounting:Cable, Gender:Plug, Receptacle, Contact Material:Brass, Contact Plating:Tin , RoHS Compliant: Yes 制造商:Thomas & Betts 功能描述:Quick Disconnect Terminal 18AWG 13.66mm Kit
LD300 制造商:Aim & Thurlby Thandar Instruments 功能描述:ELECTRONIC LOAD DC 80V 300W 制造商:Aim & Thurlby Thandar Instruments 功能描述:ELECTRONIC LOAD, DC, 80V, 300W 制造商:Aim & Thurlby Thandar Instruments 功能描述:DC ELECTRONIC LOAD; DC Load Type:Fixed; Operating Voltage Range:0V to 80V; Operating Current Range:0A to 80A; Power Rating:320W; Meter Display Type:LED; Operating Temperature Max:40C; Operating Temperature Min:5C ;RoHS Compliant: NA
LD-300CBG2-C5 制造商:CREE 制造商全称:Cree, Inc 功能描述:Mini-Dorado LED
LD-300CBGL2-C5 制造商:CREE 制造商全称:Cree, Inc 功能描述:Mini-Dorado LED
LD-300CBL2-C5-MT 制造商:MARKTECH 制造商全称:Marktech Corporate 功能描述:SPECIFICATION FOR COTCO LED LAMP