INPUT SPECIFICATIONS (1)
Description
Input Voltage Range (3)
Minimum Turn-On Voltage
Drop out Voltage
Maximum Input Current
Minimum input current (for on-state)
Input Resistance
Turn-on time (4)
Turn-off time
Min/Max stranded/solid wire
GNRxxDx
4-32 VDC
4.0 VDC
1.0 VDC
19mA
16mA
Current Regulated
8.33ms
8.33ms
24/16AWG
GNRxxBx
90-140VAC
90 Vrms
10 Vrms
23mArms
6mArms
Current Regulated
20ms
30ms
24/16AWG
GNRxxAx
180-280VAC
180Vrms
10 Vrms
23mArms
8mArms
Current Regulated
20ms
30ms
24/16AWG
GENERAL SPECIFICATIONS
Description
Ambient Operating Temperature Range (3)
Ambient Storage Temperature Range
Input to output isolation
Input/output to ground isolation
Input to output capacitance
Housing Material
Status Indicating Display
Weight (typical)
Parameters
-20 to 80 °C
-40 to 100 °C
4000 Vrms
2500 Vrms
8 pF
UL 94V0 (self extinguishing)
Green LED
0.5lbs (225 g)
GENERAL NOTES
1) All parameters at 25°C unless otherwise specifie d.
2) Off-State dv/dt test method per EIA/NARM standard RS-433, paragraph 13.11.1
3) For 180-280VAC control, maximum Ambient operating temperature is 60°C
4) Random turn-on time R suffix is 100μs (for DC control only).
相关PDF资料
PDF描述
4608X-101-184LF RES ARRAY 180K OHM 7 RES 8-SIP
282928-1 TERM BLOCK ADH LABEL 10POS 1-10
GNR20DCR SSR GNR 22.5MM 480VAC
KP01.1113.11 MOD PWR INLET W/SW PCB 2.5-3 PNL
5110/70C SL005 CABLE 22 AWG 70 COND 100' SHLD
相关代理商/技术参数
参数描述
GNR20DHZ 功能描述:固态继电器-工业安装 4-32 VDC RoHS:否 制造商:Crydom 控制电压范围:4 VDC to 32 VDC 负载电压额定值:7 VDC to 72 VDC 负载电流额定值:160 A 触点形式: 输出设备:SSR 安装风格:Panel
GNR20S201J4 制造商:未知厂家 制造商全称:未知厂家 功能描述:Catalog number system
GNR20S201JA 制造商:未知厂家 制造商全称:未知厂家 功能描述:Catalog number system
GNR20S201JC 制造商:未知厂家 制造商全称:未知厂家 功能描述:Catalog number system
GNR20S201JR 制造商:未知厂家 制造商全称:未知厂家 功能描述:Catalog number system