参数资料
型号: 81533001
厂商: Crouzet USA
文件页数: 2/16页
文件大小: 0K
描述: PNEUM MOUNT ACCESS DOMINO CLIP
其它有关文件: Declaration of Conformity
标准包装: 1
系列: *
其它名称: 81533001-ND
966-1289
General characteristics
Operating fluid
- Compressed air or inert gas.
Conditions of use
- Operating pressure 2 at 8 bars (except for special conditions).
- Fluid: Filtered air to 50 microns - non lubricated.
- Operating temperature from - 5° C to + 50° C (under + 5° C the
dew point must be below 10° C for the application).
- For optimum performance, the elements should be inter-connected
by air supply tubing with an internal diameter ≥ at 2.5 mm.
Mounting recommendations
- The elements should be mounted and piped in a clean atmosphere
in order to prevent any form of pollution entering the system.
- Minimum torque for element fixing screws:
5 cm/kg.
- maximum torque for element fixing screws:
10 cm/kg.
Characteristics common to all elements in the modular system
- The characteristics have been obtained with a supply pressure at 6
bars.
- The flow in NI/min is the number of litres of air at normal atmosphe-
ric pressure obtained with the output open to atmophere and the
supply pressure at 4 bars
- The consumption in NI/min is the number of litres of free air neces-
sary for the unit to function.
- kV = the flow coefficient of the equipment.
- Mechanical life > 10 7 operations.
Sequencer modules
flow graphs
? of passage (mm)
P. supply pressure :
4 bars
P. supply pressure:
6 bars
Module with auto reset
Flow
(NL/mn)
4
Operation results from the combination of a sequential cycle. A
system comprises individual modules which are joined together by
means of a sub-base. Each module has a memory which delivers an
output signal and receives an input signal.
An indicator on each module allows the operator to monitor the pro-
gress of the cycle and identity quickly and easily any fault which may
occur.
Brake
This returns the memory spool to the reset condition only when the
supply is lost
Shift register
The general principle is to advance the sequencer step by command
impulses to the inputs of the even steps, alternating with the command
impulses to the inputs of the odd steps.
Operation results from the combination of three functions (memory,
AND and OR) which constitute each module.
The memory activates the output and gives priority to the reset signal.
The AND element ensures the transition to the next module but only if
an input signal is present.
The OR element ensures the resetting of all previously operated
modules
Function diagram
Used for example on a transfer machine to shift the information "bad
component" collected at a test-test "n" steps further along the machine
to a reject station.
Function diagram
Auto reset sequencer module
sequencer module with maintained reset
Brake
This maintains the memory spool in position only when the supply is lost.
42
www.crouzet.com
相关PDF资料
PDF描述
LH6927R LAMP INCAN PNL MNT T3 1/4 RED
ASFL1-11.0592MHZ-EK-T OSCILLATOR 11.0592MHZ 3.3V SMD
801-1030-0331-504 INDICATOR PRESS TO TEST
657-1802-103F LED 17.46MM BLUE DIFF PANEL MNT
657-1804-103F LED 17.46MM BLUE DIFF PANEL MNT
相关代理商/技术参数
参数描述
815-33-1 制造商:Fox Electronics 功能描述:
815-33-4 制造商:Fox Electronics 功能描述:- Cut Tape Product
81533501 功能描述:PNEUM MOUNT ACCESS DOMINO HINGE RoHS:是 类别:工业控制,仪表 >> 配件 系列:* 标准包装:1 系列:Aero-Motive® 130117 附件类型:拖车带 适用于相关产品:标准盒式跟踪系统 其它名称:WM6183
815336N001 制造商:TE Connectivity 功能描述:228A053-3-00-0 - Bulk
81533RS 制造商:Nuvotem 功能描述:Transformer Toroidal 30VA 2x25V