参数资料
型号: 2420-31-G
厂商: Bourns Inc.
文件页数: 1/2页
文件大小: 0K
描述: CENTRAL OFFICE PROTECTOR GDT
产品变化通告: 2410,2420 Series Terminal Change Jun/2011
产品目录绘图: 24xx-31-G Top
24xx-31-G Side
24xx-31-G Bottom
标准包装: 100
系列: 2420
电压 - DC 击穿(标称值): 350V
脉冲放电电流 (8/20us): 20kA
极数: 3
故障短路:
安装类型: 通孔
封装/外壳: 模块,插入式
包装: 散装
电流 - AC 放电(标称值): 10A
■ Balanced TRIGARD protection
■ per UL 497 (File: 53117)
Features
■ Superior protection at a low price
?
■ Patented Switch-Grade Fail-Short device
■ Quick response and high energy handling
■ Low capacitance (<2.5 pF) - ideal for high-
speed networks in high exposure
environments
■ Meets test requirements of Telcordia
GR 974, GR1361, SBC SR 5165 and
RUS PE-80
■ Telcordia Analysis report DA-1547
?
C UL US LISTED
■ Solid brass, gold-plated pins
■ Test point access option
■ Sealed option for harsh environments
2420 Series - 5-Pin Gas Discharge Tube (GDT) Protector
The Bourns ? 3-type Model 2420 overvoltage protection modules utilize Bourns’ proprietary high-ef?ciency gas discharge tube with our
patented Switch-Grade Fail-Short mechanism to provide robust and reliable surge and thermal overload protection at a very
competitive price. The 2420 Series is based on Bourns’ three-terminal common chamber GDT. This design provides greatly
improved and balanced turn-on characteristics for overvoltage protection. The GDT is UL listed for use without a back-up
device. Air back-up devices can become contaminated; the circuitry of the 2420 eliminates the air back-up gap and thus the possibility of
its contamination. Our unique Switch-Grade Fail-Short device provides more reliable thermal overload protection compared to com-
monly used solder pellet or insulation burn-through designs.
Bourns ? Model 2420 Series 5-pin protectors can be used universally for broadband voice and data circuits including ADSL, ADSL2+,
VDSL, VDSL2 and high-speed Ethernet. The 2420 Series is an economical, reliable and low capacitance choice for overvoltage
protection of copper pair circuits.
Characteristics
Test Methods per UL 497, CSA C22.2, Telcordia GR 974, 1361 and SBC SR 5165.
DC Breakdown ............................................................................................................................................... 280-420 V
AC Breakdown @ 60 Hz ................................................................................................................................ 280-420 V
Impulse Breakdown
100 V/μs .................................................................................................................................................... 625 V
1000 V/μs .................................................................................................................................................. 875 V
Insulation Resistance @ 100 Vdc .................................................................................................................. >1 GΩ
Insertion Loss @ 100 MHz ............................................................................................................................. Exceeds Category 5
Return Loss @ 100 MHz ................................................................................................................................ Exceeds Category 5
Capacitance Tip to Ring @ 1 MHz ................................................................................................................. <1.25 pF typical
Capacitance Tip or Ring to Ground @ 1 MHz ................................................................................................ <2.50 pF typical
Impulse Reset 1
52 V, 260 mA ............................................................................................................................................. <10 ms
135 V, 200 mA ........................................................................................................................................... <10 ms
150 V, 200 mA ........................................................................................................................................... <150 ms
Impulse Life Characteristics (Tip and Ring to Ground Simultaneously)
10 A, 10/1000 μs ....................................................................................................................................... >3000 operations
100 A, 10/1000 μs ..................................................................................................................................... >300 operations
300 A, 10/1000 μs ..................................................................................................................................... >100 operations
500 A, 10/1000 μs ..................................................................................................................................... >400 operations 2
2,000 A, 10/250 μs .................................................................................................................................... >25 operations
5,000 A, 20/100 μs .................................................................................................................................... >2 operations
20,000 A, 8/20 μs ...................................................................................................................................... >1 operation
AC Life Characteristics (Tip and Ring to Ground Simultaneously)
0.5 A rms continuous ................................................................................................................................. >30 seconds
1 A rms, 1 second, 600 ft. cable ................................................................................................................ >60 operations
1 A rms, 1 second, 1 mile cable ................................................................................................................. >60 operations
10 A rms, 1 second .................................................................................................................................... >5 operations
65 A rms, 11 cycles .................................................................................................................................... >1 operation 2
120 A rms, 0.1 second ............................................................................................................................... 1 operation
High Current Capability and Thermal Operation (Tip and Ring to Ground) .................................................... >30 A rms, 15 min.
Storage and Operating Temperature .............................................................................................................. -55 to +85 °C
Telcordia analyzed for controlled (non-sealed) and uncontrolled, high-exposure (sealed) environments per GR 974 and SBC SR 5165.
Telcordia Technical Analysis Report DA-1547.
Notes:
1
2
Network applied
Per RUS PE-80
Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
Speci?cations are subject to change without notice.
Customers should verify actual device performance in their speci?c applications.
相关PDF资料
PDF描述
243-220-301 CARD GUIDE
2447 CONN BNC MALE PANEL MOUNT .531"
2451 RECEPTACLE BNC FEMALE PANEL
2455 CONN N FEMALE RECEPTACLE PANEL
24FMN-SMT-A-TF CONN FMN HOUSING 24POS SIDE SMD
相关代理商/技术参数
参数描述
242031GS 制造商:BOURNS 制造商全称:Bourns Electronic Solutions 功能描述:5-Pin Gas Discharge Tube (GDT) Protector
2420-31-G-S 功能描述:气体放电管 - GDT /气体等离子体避雷器 BLACK SEALED 52.32mm RoHS:否 制造商:Bourns 峰值脉冲电流: 直流击穿电压(标称):4500 V 电极数量:2 系列:SA2 端接类型:Axial 故障安全保护 Y/N: 封装:Reel
242031GST 制造商:BOURNS 制造商全称:Bourns Electronic Solutions 功能描述:5-Pin Gas Discharge Tube (GDT) Protector
2420-31-G-ST 功能描述:气体放电管 - GDT /气体等离子体避雷器 BLACK SEALED 52.32mm RoHS:否 制造商:Bourns 峰值脉冲电流: 直流击穿电压(标称):4500 V 电极数量:2 系列:SA2 端接类型:Axial 故障安全保护 Y/N: 封装:Reel
242031GT 制造商:BOURNS 功能描述:New